Page 116 - BSR17-EN
P. 116
Borusan
Mannesmann
Gemlik SP Plant
Energy Efficiency
To reduce the loss by 10% in spiral production
and coating plant air pressure lines we imple-
mented a 15 thousand TL investment which
led to 90 thousand kWh/year energy saving
and 24 thousand TL saving accordingly. Our
annual greenhouse gas emissions dropped to
45 tons of CO e.
2
Borusan Mannesmann Gemlik
ERW Plant Cooling Water
Closed Circulation
In order to reduce unnecessary
energy consumption and down-
time, by doing closed circulation
in SRM furnace inductors cooling
water reverse circulation pump line
and using 7.5 kWh scuba pump in-
stead of 55 kWh centrifugal pump
we targeted 86,4% improvement
in energy consumption. As a result
of improvement, we achieved 269
thousand kWh energy saving and
67 thousand TL saving accord-
ingly. Our annual greenhouse gas
emissions dropped to 133 tons of
CO e.
2
116